Subject Re: [IBO] TIB_Event Alerter Problem and Application Exit
Author Jason Wharton
I know that using the GDS32.DLL that came with IB 5.11 and the IB 5.6 server
on NT I don't have any problems using events. Nor are there any problems
using LIBS on any platform and version. So, I draw the conclusion from this
that the little code there is in IBO is correct and that if there are
problems using another configuration it is something unrelated to the code
in IBO.

I would like to suggest that this issue be taken to the general InterBase
support lists and hopefully to the people in the OS community that can
potentially fix this whole mess.

Regards,
Jason Wharton
CPS - Mesa AZ
http://www.ibobjects.com


----- Original Message -----
From: "Marius Popa" <mpopa@...>
To: <IBObjects@yahoogroups.com>
Sent: Wednesday, February 28, 2001 12:55 PM
Subject: Re: [IBO] TIB_Event Alerter Problem and Application Exit


> well ..
> someone on the arhitect list said that events are bad (Jim Starkley)
> so from then i don't use events
> you could do the same things with some soket programming ...
> a lot of work for that

>
>
> 28.02.2001 13:31:06, "Chris Hulsey" <chulsey@...> wrote:
>
> >Hello,
> >
> >I am experiencing a strange problem with the TIB_Event control for
> >Interbase. I'm building an application using Borland C++ Builder 5.0 and
> >IBO components to access an IB Server 6.0. I'm using an Event Alerter to
be
> >aware of the modifications made by other users, so that I can refresh a
view
> >screen that outputs data on a grid. My application actually register's
the
> >TIB_Event control successfully and the OnEventAlert executes correctly
when
> >the event is posted on the server using POST_EVENT "eventname" from
within a
> >TRIGGER or STORED PROCEDURE. But, every now and then when I try to
exit
> >my application it does not completely exit and is still running according
to
> >the Borland IDE. At this point I have to do a Program Reset from the
> >Borland IDE, then I cannot connect to my Interbase Server anymore even
from
> >another station until I actually shutdown the Interbase Server Program
and
> >Restart the Interbase Server Program from the Interbase Manager program.
I
> >thought it might be that I have not UnregisterEvent before exit, but I
put
> >this in and I still get this random problem.
> >
> >I am connecting with a TIB_Database control to a remote server via TCPIP
and
> >the TIB_Event control points to this connection via the IB_Connection
> >property.
> >
> >I installed Interbase Client 6.0 on my client machine with the latest
> >(gds32.dll) and this still happens.
> >
> >My Configuration is as follows:
> >
> >Client Station
> >Pentium III 800 Mhz - 256MB Ram
> >Windows 2000 Professional
> >Borland C++ Builder Enterprise 5.0
> >Interbase Client 6.0
> >
> >Server Station
> >Pentium III 800 Mhz - 512MB Ram
> >Windows 2000 Server
> >Interbase Server 6.0
> >
> >Any suggestions??
> >
> >Thanks in advance,
> >
> >Chris Hulsey
> >chulsey@...
> >
> >
> >
> >
> >
> >Your use of Yahoo! Groups is subject to http://docs.yahoo.com/info/terms/
> >
> >
>
>
>
>
>
>
>
> Your use of Yahoo! Groups is subject to http://docs.yahoo.com/info/terms/
>
>