Subject Re: [IBO] AV on 95 machine
Author Scott Taylor
Ed Dressel said:
> I have a user with a Win 95 machine that is getting an AV with the
> following stack (stack comes from madExcept):
>
> 00ed8f49 IBO40CRT_D7.BPL Ib_components TIB_Connection.API_Connect
> 00ed7438 IBO40CRT_D7.BPL Ib_components TIB_Connection.SysConnect
> 00ed4c81 IBO40CRT_D7.BPL Ib_components TIB_Connection.Connect
> 00ed4d6d IBO40CRT_D7.BPL Ib_components TIB_Connection.Open
> 006afeca TRAK.EXE Master TfrmTRAKMaster.SetDataPath
> ...
>
> the database config seems to be correct--anything I might look at?

I'll guess the gds32.dll is wrong version.

So is the OS =P

--
Scott