Thanks for the assistance!
I'll make this the default behavior.
Jason Wharton
CPS - Mesa AZ
http://www.ibobjects.com
I'll make this the default behavior.
Jason Wharton
CPS - Mesa AZ
http://www.ibobjects.com
----- Original Message -----
From: "Tomas MichalĂk" <michalik@...>
To: <IBObjects@yahoogroups.com>
Sent: Monday, December 10, 2001 8:29 AM
Subject: Re: [IBO] IBO service app problem - prevents NT shutdown
> Hi Jason,
>
> Jason Wharton wrote:
> >
> > I've discovered the same problem and I am still working on resolving it.
> > If anyone has any ideas what would cause this I am keenly interested.
> >
> > Note: For me it only seems to interrupt a log-out from a logged in
console
> > session but a request to shut the server down is respected.
>
> Yes, you are right. Shutdown is respected, logoff is not. When trying
> different things I deleted the call to inherited ServiceShutdown handler
> in my descendant ...
>
> However I tried to look for some solution in the news archive and
> although I've seen a few suggestions, nothing works on my NT4-SP6. Then
> I found out that simply running the service as non-interactive helps
> (logoff succeeds). I also found that on NT4 it is not recommended to run
> interactive services containing controls from comctl32.dll (see
> http://support.microsoft.com/directory/article.asp?ID=KB;EN-US;Q238721).
> As I don't need an interactive service at the moment I can use what's
> currently avilable.
>
> Regards,
> Tom
>
> =================================
>
> Tomas Michalik
> ProCA, s. r. o.
> V Luzich 818, Praha 4
> Czech Republic
>
> e-mail: michalik@...
> tel: +420 2 67283446
>