Subject | Events on FB2.1 Classic |
---|---|
Author | Sándor Tamás |
Post date | 2010-12-15T16:09:02Z |
Hi,
We run into a problem which is really disturbing.
We have FB2.5 Classic installed on a Windows server.
Step 1.: modify some data which fires an event
Step 1.5: the connected clients get the event (as expected)
Step 2: create a new connection from a previously not connected client
Step 3: it gets the event as if it was connected at the time of the
event (as unexpected .... very unexpected)
Can it be true? Because we experienced it, and don't know what to do. It
cannot be produced under super or superclassic, and none of the previous
versions of FB.
Thanks,
SanTa
[Non-text portions of this message have been removed]
We run into a problem which is really disturbing.
We have FB2.5 Classic installed on a Windows server.
Step 1.: modify some data which fires an event
Step 1.5: the connected clients get the event (as expected)
Step 2: create a new connection from a previously not connected client
Step 3: it gets the event as if it was connected at the time of the
event (as unexpected .... very unexpected)
Can it be true? Because we experienced it, and don't know what to do. It
cannot be produced under super or superclassic, and none of the previous
versions of FB.
Thanks,
SanTa