Subject "Internal gds software consistency check (page in use during flush (210))"
Author Bob Murdoch
I'm using FB1.5 (release version) in Classic mode on a new multiprocessor
Windows2003 server with 1GB of ram.

The database is 10GB, page size 8192, buffers 2048.

I'm running it in test mode right now to see how the Classic version
behaves. I just came across this problem in the logs:

Internal gds software consistency check (page in use during flush 210))

In the 15 seconds prior to this message in the log, there are two 10061
connect errors, and then a 'Guardian starting' message.
According to the few messages I can find about this error (none of them
recent), this kind of message usually is reported along with a corrupt
database complaint.

Can someone give me a clue as to what this message means, and what can be
done to prevent it?

tia,

Bob M..