Subject Re: [ib-support] strange SQL error - internal gds software consistency check
Author Ann W. Harrison
At 09:41 AM 11/5/2001 -0600, Mark Meyer wrote:

>our QA department has been reporting the following error:
>
>"General SQL error. Internal gds software consistency check (can't continue
>after bug check)".
>
>can someone explain to me what the error message means and what may be the
>potential cause?

An unexpected internal error is called a "bugcheck" for reasons going
far back into history. When a connection encounters one of the "bugcheck"
errors, it is marked as corrupt and every action it takes thereafter
will return the error above. In all cases, there was an earlier error.
Check interbase.log (or interbas.log) in the install directory - you'll
see the "can't continue" errors and immediately before them there should
be an error will help us diagnose the problem


Regards,

Ann
www.ibphoenix.com
We have answers.