Subject RE: [IBO] 4.9.14b32 - Problem with executable SP and output parameters
Author IBO Support List
Thomas,

This is due to there being no SUSPEND in the body of the procedure.

I have put in a request to enhance Firebird to provide an implicit SUSPEND
if one is not included in the body of the procedure and there are output
fields. So far it doesn't appear that this issue is being given much
consideration.

Jason

-----Original Message-----
From: IBObjects@yahoogroups.com [mailto:IBObjects@yahoogroups.com] On Behalf
Of Thomas Steinmaurer
Sent: 09 January 2012 12:04 AM
To: IBObjects@yahoogroups.com
Subject: Re: [IBO] 4.9.14b32 - Problem with executable SP and output
parameters

Hello Jason,

> migrating a legacy app from D2006 to D2010 for Unicode support.
> Currently I'm using 4.9.14b32.
>
> I have an executable SP (no SUSPEND in the SP) with a few input
> parameters and one output parameter:
>
> SET TERM ^^ ;
> CREATE PROCEDURE P_1 (
> ...
> )
> returns (
> VAR_ID Numeric(18,0))
> AS
> BEGIN
> VAR_ID = GEN_ID(MYGEN, 1);
> ...
> END ^^
> SET TERM ; ^^
>
>
> In the application I'm using a TIB_StoredProc and:
>
> ...
> myProc.ExecProc;
> ...
> myVar := FieldByName('VAR_ID').AsInt64;
>
>
> While this has worked in previous IBO versions, even in earlier 4.9.14
> versions, with b32, myVar is always 0.
>
> Any ideas?

Did you have time to investigate?


Thanks,
Thomas