Subject Re: internal gds software consistency check (cannot start thread)
Author Adam
--- In firebird-support@yahoogroups.com, "Paul Hope" <paulhope@...> wrote:
>
> Hi Adam
> >
> > > No. It's exactly the same for Firebird Superserver. A
> > 32-bit process
> > > is a 32-bit process. However, the cure for Firebird has another
> > > option - use Classic.
> >
> > I must admit I had not considered this option. Having little
> > experience with Classic (just installed now on my laptop),
> > what are the gotchas I need to know about? I know I may need
> > to disable Guardian. I have read the release notes and
> > nothing stands out. The absence of local connection is fine,
> > it doesn't work under terminal server anyway.
> >
> WRT Classic gotchas - We (and another contributor to this ng) found
that we
> could not make changes to stored procedures in classic without
shutting down
> and clean starting - got an 'object in use' error.

Thanks Paul,

I will be sure to test this before moving the production servers
across. I noticed the installer left guardian running on my laptop
which I know is bad. The object in use should only happen if there is
an active transaction that has referenced that procedure.

> May not be a problem for
> you - is a show stopper for us.

Probably not quite a showstopper when compared to 'hey the server has
crashed and now 30 customers cant access their databases', but yes
that would be very annoying when it comes to upgrades.