Subject RE: [firebird-support] Problem calling set generator...
Author Nigel Weeks
Alternatively, push it up a level - to it at the application layer, rather
than the DB layer:

Nige

-----Original Message-----
From: firebird-support@yahoogroups.com
[mailto:firebird-support@yahoogroups.com]On Behalf Of Alan McDonald
Sent: Tuesday, 7 November 2006 5:16 PM
To: firebird-support@yahoogroups.com
Subject: RE: [firebird-support] Problem calling set generator...


> Hi, (This is Firebird 1.5.3)
> I have an 'empty' database with a 'prefs' table which has a pk
> 'prefs_sn', and a generator 'gen_prefs' which is initially set to 1.
> I have a routine which copies all rows of the prefs table from one DB
> into another (ALL columns, including the pk's).

a better idea is to NOT include the PK field in the copy process. The PK
will be re-generated - no need to fiddle any more
Alan