Subject Re: Classic Server & not correct closed connections
Author gbehnke2000
Eduardo,

unfortunately not yet. Might be if have more time i plan to write a
service which checks the ip-connections in conjunction with the fb-
process. The i'll make a ping to the ip-adress. If there comes no
answer i'll kill the fb-process

Best regards
Gerhard

--- In firebird-support@yahoogroups.com, "etijerinacano"
<etijerina@m...> wrote:
>
> Hi.-
>
> Same problem here, have you found any solution yet?
>
> TIA,
> Eduardo Tijerina
>
> --- In firebird-support@yahoogroups.com, "gbehnke2000"
<Behnke@h...>
> wrote:
> >
> > Dear Members,
> >
> > to improve the performance in conjunction with a
> Multiprocessorsystem
> > we changed successfully from Superserver to Classicserver. We
have
> no
> > problems with one exception:
> > In the case that a client dos'nt close correctly (might be trough
a
> > crash) the db connection, the fb-process "FB_inet_server.exe"
keeps
> > open. Therefore from time to time (approximately every four
weeks)
> we
> > shut down the server to close all unnecessary connections.
> > Is there another way to find out what fb processes can be killed
> > respectively for the future of the development of fb can this be
> done
> > automatically from fb ?
> >
> > Many thanks
> >
> > Gerhard Behnke